ADMS Installation: Problem bei der Vorabprüfung bei der ASP Prüfung

During the pre-checks portion of the Autodesk Data Management Server 5 (ADMS) installation, you received the following error message:

ASP Check: The Underlying Connection was closed

Solution

This pre-check message normally occurs if the pre-checks program cannot communicate with the Internet Information Services (IIS) server.

Verify that you can open normal web pages:

  1. Open a web browser on the computer on which you are trying to install ADMS.
  2. Enter http://localhost in the Address bar of the browser.
  3. If you receive a message that the page cannot be found, try the same steps, but enter the following into the browser instead: http://<ip address of vault server>.
  4. If the IP address works, check the following registry key:HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\HTTP\Parameters\ListenOnlyList
  5. Make sure that the ListenOnlyList value does not exist. If it does exist, delete it.

After modifying the registry, follow these steps to have the changes take effect:

  1. Open a Windows command line window.
  2. Enter net stop http /y
  3. Enter net start w3svc
  4. Enter IISRESET

“ASP Check: Underlying Connection was closed” error occurs during installation pre-checks

Wo sehe ich welcher Service Pack bei Inventor 2010 installiert ist?

In Inventor 2010, Product Information from Help menu > About will not show the level of service pack installed.

To find out the service pack level, go to

  • Windows XP: Start menu > Control Panel > Add/Remove programs >  Enable Show updates.
  • Windows Vista: Start menu > Control Panel > Programs and features > Click on view installed updates.

Any service pack installed will be displayed under Inventor 2010.

What version/service pack level of Inventor 2010 is installed

Probleme beim Einfügen eines Halbzeuges im Gestell-Generator

Sollte eine Fehlermeldung beim Einfügen eines Profiles mit dem Gestell-Generator kommen, liegt das daran, das keine Inhaltscenter-Bibliothek mit Profilen vorhanden ist. Das sind:

  • ANSI
  • DIN
  • ISO
  • GOST
  • JISGB

Problems encountered while executing Frame Insert command

AutoCAD 2009 Benutzereinstellungen zurücksetzen

  1. Click Start menu (Windows) > Run.
  2. In the Run dialog box, enter regedit
  3. In the Registry Editor, locate the following subkey and delete it:AutoCAD 2009:HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R17.2\ACAD-7001:xyz

    Where xyz are numbers and characters that vary depending on the installed language version of AutoCAD 2009.

Resetting default user settings in AutoCAD 2009

ACADM: Diese Zeichnung wurde zuletzt ausserhalb von AutoCAD Mechanical gespeichert

Meldung abschalten: EXPERT = 5

When you open a drawing in AutoCAD® Mechanical, the following message is displayed:

This drawing was last saved outside of AutoCAD Mechanical. ..... Objects added to the drawing will not be affected. Would you like to continue? Yes or No.

You want to know if it possible to suppress this message by default.

Solution

This prompt is displayed because a structure drawing containing Mechanical objects is saved in Vanilla AutoCAD and then reopened in AutoCAD Mechanical.

In order to suppress this prompt, you can set the variable EXPERT to a value of 5.

Suppressing prompt for the message “This drawing was last saved outside of AutoCAD Mechanical..”

Vault: “Letzte Version abrufen” holt keine Bibliotheksteile

Issue

When you right-click a parent Inventor file (IAM, IDW, or IPN), and select Get Latest or Edit (Open) on the shortcut menu, you have noticed that there are no Library files included in the list of files to be retrieved from Vault.

Solution

This behavior is “as designed.” Vault Explorer assumes that all the library files for the various supported client applications are already in the project files Library locations.

When using Vault or Productstream for Inventor files, it is strongly recommended that you use the Open From Vault command in Inventor, which will retrieve all the files required to open the parent or referencing file. Once all the files are local, the active project file in Inventor is used to resolve all files correctly.

Get Latest Version from Vault Explorer does not include Library Files

Fehlermeldung bei der Installation von SP2 für Inventor 2009

Wenn bei der Installation des SP2 für Inventor 2009 eine Fehlermeldung kommt, das der Service Pack nicht installiert werden kann, dann liegt das möglicherweise daran, das das Inventor Client Update (für den Zugriff auf den ADMS 2010) installiert ist.

Issue

When you tried to apply Service Pack 2 to Inventor 2009, you received the following error message, despite having downloaded the correct patch:

This hotfix is only for Autodesk Inventor 2009 Service Pack 1 and can not be applied to other versions of Autodesk Inventor.

Solution

To resolve this issue

  1. Uninstall the Autodesk Inventor 2009 SP1 Client Upgrade for Autodesk Vault Server 2010.
    Note: If you do not see this entry in your Windows Add or Remove Programs, be sure click View Installed Updates on Windows Vista or select the Show Updates check box on Windows XP.
  2. After the Client Upgrade has been uninstalled, you can download and install the updated Inventor 2009 Service Pack 2 Client Update for Autodesk Data Management Server (ADMS) 2010.

Error when applying Service Pack 2 to Autodesk Inventor 2009

Größe der Vorschau im Vaultexplorer wird nicht komplett genutzt

Wenn es so im Vault Explorer aussieht, dann die DPI Zahl in Windows auf 96 setzen.

To resolve this issue, follow these steps:

  1. Right-click the desktop. Click Properties.
  2. On the Settings tab of the Display Properties dialog box, click Advanced.
  3. On the General tab, set the DPI to Normal size (96 DPI).

You may be prompted to restart your computer. If you are, these changes will not take effect until you do so.

Graphic on View tab is not maximized to fill entire graphic window